Annual programme

Annual plant-wide leakage survey of compressed air system outlining potential financial savings

Annual plantwide leakage survey of compressed air system

Repaired vs OutstandingLeakage management programme: 

  • Annual plantwide leakage survey of compressed air system
  • All leaks detected are graded, 1,2 or 3 and tagged on-site
  • Associated cost of leakages is calculated
  • Minor repairs are carried out during the survey
  • Comprehensive repair report is issued within 5 days of survey completion

Total annual costs

€2,400

Potential Cost Savings from Leakage Management Programme

€15,661

Grade

1

2

3

Total                                 

Annual Leakage €

Total

53                                 

35                                 

11                                 

99

15661

Area1 P1

7

2

0

9

538

Area2 P4

5

4

0

9

788

Area3 P3

11

7

5

23

5301

Area4 Plant Room 1

1

3

1

5

1273

Area5 Plant Room 2

15

8

1

24

2506

Area6 Roof

0

1

0

1

157

Area7 WWTP

2

1

4

7

3301

Area8 P4

3

5

0

8

881

Area9 Warehouse

1

0

0

1

32

Area10 Tank Farm

7

4

0

11

852

Area11 Boiler House

1

0

0

1

32